Heat Shield Deflector for existing Wooden Mantel Shelf Beams – Bare Self Finish
Custom non-combustible heat shield deflector for existing fireplace mantle beams - Self Finish
Non Combustible Heat Resistant Shield Deflector Plate - supplied undrilled with heat grade steel screws and spacers.
This great heat shield deflector allows the mantel to be much closer than standard timber mantle beams (read below for more info). perfect for above a wood burner, inset stove, open fires, mantelpiece stoves, kitchen chimney hoods, and more. Allowing to place your wooden beam lower while still adhering to current building regs.
Very popular for those who have a beam in place and have a new stove fitted which needs to comply to new UK building regs also a great choice for those fitting a tv above the stove.
• Can be positioned as close as 150mm from the heat source, much closer than unshielded beams
• Heat shield allows low heat conduction meaning the wood top remains cool/warm
• Supplied with everything needed. black 12mm heat resistant spacers, screws and easy to follow instructions
• Delivered fully insured and traceable online
• custom sizes to suit your needs
-Custom Length-
800mm up to 1450mm
-Custom Depth - (wall to front)
35mm to 200mm
-Thickness-
2mm
These sizes are made from my stock steel so the price is the same regardless of size, need it longer or deeper? no probs just get in touch for a quote..
-Materials included-
12mm heat resistant spacers to allow airflow between materials
Heat grade steel plate shield
Screws
-Tools Required:-
5 mm metal drill
Cross-head screwdriver
-Finishing Instructions:-
Shield supplied with sharp, mill-cut edges—handle with care.
File or sand edges, then clean with white spirit or acetone.
Drill 5 mm holes for spacer placement. Supplied with 8 or 10 depending on length
Recommended spray with stove paint or other heat-resistant paint.
-Placement-
The heat shield should ideally cover the entire underside of the mantel.
Recommended distances from heat source to allow for adequate air flow and adhere to current UK building regs.
300mm from inset/cassette stoves, but may be reduced to 250mm if appliance manufacture guidance allows.
or
1.5x the diameter of a wood burner flue. For example, a 4-inch flue would require a distance of 150mm or a 5-inch would require 190mm, etc. The flue is considered a heat source (unless insulated), so the mantel should be placed at a distance, diagonally or vertically measured from the flue to the underside of the mantel shield.Current building regs stipulate that unshielded mantels require 450mm+ clearance or 3x the flue diameter, so our shielded versions allow around 50% reduction.
Note: the above is based on UK building regulation guidance and top brand stove manufactures recommendations. You should always refer to your specific appliance manufacturers' guidance for safe clearances to heat shield/deflector mantels.
Any questions, just get in touch.