top of page
Custom Heat Shield Deflector for Existing Fireplace Mantle Beams - Ready to Fit

Custom Heat Shield Deflector for Existing Fireplace Mantle Beams - Ready to Fit

Non Combustible Heat Shield Deflector- in Black Heat resistant paint supplied with screws and spacers, square corners

 

This great heat shield deflector allows the mantel to be much closer than standard timber mantle beams (read below for more info). perfect for above a wood burner, inset stove, open fires, mantelpiece stoves, kitchen chimney hoods, and more. Allowing to place your wooden beam lower while still adhereing to current building regs.

 

Very popular for those who have a beam in place and have a new stove fitted which needs to comply to new UK building regs also a great choice for those fitting a tv above the stove.

 

• Designed & Handmade by me Stuart Poole at my rural workshop in Hampshire UK

• Can be positioned as close as 15cm from the heat source, much closer than unshielded beams

• Heat shield allows low heat conduction meaning the wood top remains cool/warm

• Supplied with 12mm spacers and screws

• Delivered fully insured and traceable online

• custom sizes to suit your needs

 

-Finish-

Smooth surface finished in a heat resistant. semi matt Black paint

 

-Lengths-

Custom lengths: 70cm up to 200cm

 

-Depth - (wall to front)

7.5cm-20cm

 

-Thickness-

3mm

 

Select the size window from the drop down menu then add your preference in the personalisation box, I will pick this up on order processing and make it for you to suit.

 

Like it a touch thicker or deeper? no problem, just get in touch for a quote..

 

-Material-

12mm spacers to allow airflow between materials

Steel plate shield coated in a heat resistant satin paint

 

-Placement-

The heat shield should ideally cover the entire underside of the mantel.

Recommended distances from heat source to allow for adequate air flow and adhere to current UK building regs.

30cm from inset/cassette stoves, but may be reduced to 25cm if appliance manufacture guidance allows.

or

1.5x the diameter of a wood burner flue. For example, a 4-inch flue would require a distance of 15cm or a 5-inch would require 19cm, etc. The flue is considered a heat source (unless insulated), so the mantel should be placed at a distance, diagonally or vertically measured from the flue to the underside of the mantel shield.

Current building regs stipulate that unshielded mantels require 45cm+ clearance or 3x the flue diameter, so our shielded versions allow around 50% reduction.

 

Note: the above is based on UK building regulation guidance and top brand stove manufactures recommendations. You should always refer to your specific appliance manufacturers' guidance for safe clearances to heat shield/deflector mantels.

Any questions, just get in touch.

  • Delivery:

    UK and NI

    Around 7-10 working days

    Charges calculated on checkout

PriceFrom £95.00
0/500
Quantity
    bottom of page